Hi Delta® FlexGas® - Type H
Job:
Engineer:
Contractor:
Prepared By:
Model:
Dual-Fuel Hot Water Boilers
Models 992BD-2342BD
Date:
Indoor/Outdoor:
MBTUH Input:
Fast, Economical Natural-to-Propane Gas Switchover
100% Factory Fire Tested
84% Efficiency
Maximum Outlet Temperature: 230°F
Minimum Non-Condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-Year Thermal Shock Warranty
Diagnostic Center with Fault History
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Fan-Assisted Low NOx Burners
Patented Burner Security Blanket
Patent Nos. 6,904,873 & 7,044,124;
other patents pending
Heat Exchanger
Gas Train
Burner
ƒ
ƒ
H Stamp
Headers
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Manual Gas Shut-Off Valve(s)
ƒ
Ultra-Low NOx: Less than 30 PPM
Gas Pressure Regulator
Safety Shut-Off Valve
Firing Control Valve
Low Gas Pressure Switch, Manual
Firing Mode
Temperature Controls
Glass-Lined Cast Iron – Standard
B- TempTracker Digital Controller,
4-Stage
Y-241 Electronic Sequencer, 4-Stage
Y-281 Electronic Sequencer, 8-Stage
Bronze – Option A-1
ASME Inspected and Stamped
160 PSIG Working Pressure
National Board Approved
Fin Tubing
ƒ
ƒ
ƒ
3-Stage (H8): Model 992BD
4-Stage (H9): Models 1262BD -
2342BD
Options
Copper – Standard
C-6 Ignition Module, Manual Reset
D-21 TruSeal® Direct Vent
F-10 Low Water Cut-Off, Remote
Probe
Cupro Nickel – Option A-3
ASME Steel Tube Sheet
Silicone High Temp. O-Rings
ASME Pressure Relief Valve
60 PSIG – Standard
ƒ
ƒ
Natural/Propane Gas
Gas Connection
Left – Standard
Right – Option Z-1
Design Certified ANSI Z21.13/
CSA 4.9
ƒ
ƒ
ƒ
I-1
High Limit Control, Auto Reset
ƒ
P-
Pump:
60Hz
HP, 120V, 1∅,
PSIG – Optional
ƒ
ƒ
Temperature and Pressure Gauge
Water Connections
Water Hardness:
Cast Iron
Mounted
GPG
Bronze
Loose
Rear
Venting
ƒ
Vent Location
Left – Standard
Right – Option A-6
Top – Standard
Rear – Option D-14
Vent Termination Cap
Outdoor D-11
Indoor, Horizontal D-15
Indoor, Vertical (by others)
Combustion Air
In-Line Filter Kit (TruSeal only)
D-17
Air Intake Elbow D-16
Extractor – Optional
By others
Front
P-26 Cold Water Start (See 2000.49)
S-2 High Gas Pressure Switch,
Manual
X-1 SureRack™ Kit
X-2 SureRack Add-on
Controls
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
120V, 60Hz, 1∅ Power Supply
120/24V 60Hz Transformer
100% Shut-Off/Lockout
Hot Surface Ignition
ƒ
ƒ
Remote Flame Sensor
High Limit Control, Manual Reset
On/Off Power Switch
Manual Shut-Off, Front-Mounted
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switches
Economaster Pump Time Delay
Enable/Disable
Regulatory Agency Requirements
Not required
Construction
ƒ
ƒ
Indoor/Outdoor Construction
Enclosed Front Controls
Catalog No.: 2000.313A
Effective: 11-15-07
Replaces: 8-15-07
|
PYLE Audio TV DVD Combo PLDVD10M User Guide
Rotel Stereo Amplifier RB 991 User Guide
Rotel Stereo Amplifier RC 1082 User Guide
Ryobi Laminate Trimmer TR45 User Guide
Samsung Car Video System HD948 XSS User Guide
Samsung Flat Panel Television LA32A650A1R User Guide
Sanyo Car Stereo System CH3672R User Guide
Sanyo CRT Television CE28WN3 B User Guide
Scag Power Equipment Lawn Mower SFW36 16BV User Guide
Sears Cooktop 32025 User Guide