Shark Vacuum Cleaner V1510 User Manual

Hand Vacuum With Motorized Brush  
OWNER’S MANUAL  
Model V1510  
120V., 60Hz., 6.67 Amps  
EURO-PRO Operating LLC  
Boston, MA, 02465  
Tel.: 1 (800) 798-7398  
Copyright © EURO-PRO Operating LLC 2008  
 
PRECAUTIONARY MEASURES  
OPERATING INSTRUCTIONS  
3. To use the flexible hose with the  
WARNING: Always unplug from electrical  
outlet before opening the dust cup  
(container).  
Note: HEPA dust cup filter must be used  
when operating the hand vacuum.  
IMPORTANT:If the suction opening of the hose is BLOCKED, switch off the vacuum  
cleaner and remove the blocking substance before you start the unit  
again.  
dusting brush, hold the hose in one  
hand and with the other, pull out the  
dusting brush and turn clockwise to  
lock in place. (Fig. 4)  
4. When pulling out the power plug  
from the wall outlet, pull the plug  
not the power cord.  
1. Do not operate the vacuum  
cleaner too close to heaters or  
radiators.  
Using The Unit As A Hand  
Vacuum  
1. Insert the dusting brush/hose  
connector into the brush chamber  
exhaust port. Lock the flexible hose in  
place by clipping the hose into the  
hose holder. (Fig. 1)  
Fig. 4  
4. To use the flexible hose with the  
crevice tool, make sure that the  
brush is in the storage position  
and insert the crevice tool into the  
opening of the hose. (Fig. 5)  
5. Do not pick up anything that is  
burning or smoking such as  
2. Before inserting the power plug  
into the wall outlet, make sure that  
your hands are dry.  
cigarettes, matches or hot ashes.  
6. Do not use without HEPA filter in  
place.  
Fig. 1  
7. Do not bend, trample or pull the  
hose by force. Do not operate  
with a damaged hose.  
Cleaning With the Hose  
To use the hand vacuum with only the  
hose and the dusting brush or crevice  
tool:  
1. Rotate the brush cover by pushing on  
the brush cover release button until it  
clicks in place. (Fig. 2)  
2. Remove the flexible hose from the  
brush chamber exhaust port and take  
the hose out from the hose holder.  
(Fig. 3)  
8. When vacuuming fine dust  
particles such as gyproc dust,  
flour or any other fine dust, empty  
the dust cup and "TAPCLEAN"  
the dust cup filter frequently to  
avoid over heating the motor.  
3. Before you start vacuuming, make  
sure to remove large or sharp  
objects that might damage the HEPA  
Filter.  
Fig. 5  
CAUTION: The hand vacuum is a  
very powerful unit. Make sure that you  
hold it firmly, otherwise it can slip out  
of your hand and cause injury.  
Fig. 2  
Fig. 3  
3
4
 
OPERATING INSTRUCTIONS  
OPERATING INSTRUCTIONS  
2. To open the dust cup (container),  
6. Vigorously “TapClean”  
Cleaning & Changing the HEPA  
Dust Cup Filter  
WARNING: Always unplug the unit from  
electrical outlet before opening the Dust  
Cup (container).  
IMPORTANT: Do NOT use the HEPA  
filter cartridge without the debris screen  
in place.  
WARNING: After each Use - Always  
remove the filter debris screen from the  
HEPA dust cup filter, then vigorously  
TapClean” HEPA filter until no more  
dust can be removed.  
Motor Thermostat  
push button and remove the dust  
cup (container ). (fig. 7)  
the HEPA dust cup  
filter on a hard  
surface until no more  
dust is observed  
falling out from  
between the pleats of  
the filter. (Fig. 11)  
IMPORTANT: This unit is equipped  
with a motor protective thermostat. If  
for some reason the vacuum cleaner  
should overheat, the thermostat will  
automatically turn the unit off. Should  
this occur:  
• Push the On/Off button once.  
• Disconnect the plug from the  
power source.  
• Check the source of overheating  
problem. (i.e. clogged hose or  
filter)  
• If clogged hose or filter is found,  
unclog the hose and replace the  
filters.  
• Wait at least 45 minutes before  
attempting to reuse the vacuum.  
• After unit has cooled down for  
45 minutes, plug in the cleaner  
and push the On/Off button. The  
vacuum should start again.  
• If the vacuum still does not start,  
contact customer service at  
1 (800) 798-7398.  
Dust cup release button  
Fig. 11  
7. “TapClean” the debris  
screen or rinse under  
a faucet until clean.  
(Fig. 12) Remember  
that the debris screen  
must be completely  
dry before reinstalling  
in the vacuum.  
Fig.7  
3. Rotate the lower dust cup clockwise  
to separate it from the filter  
chamber. Empty and clean the dust  
cup. (Fig. 8)  
IMPORTANT, Please Note : The  
“TapClean” HEPA dust cup filter & debris  
screen will stop most of the tiniest dust  
particles and airborne allergens from re-  
entering the air you breathe. Because of  
this incredible filtration performance, the  
HEPA dust cup filter will quickly  
accumulate, inside the white filter folds,  
many fine dust particles that are difficult  
to see but which will eventually block or  
reduce your suction power - if not  
cleaned properly. Clean the HEPA filter  
and debris screen after each use as  
described in this section.  
Fig. 12  
Debris  
Screen  
8. Replace the debris screen on the  
HEPA dust cup filter and reinstall  
Fig.8  
filter assembly in the vacuum. (Not  
shown)  
Filter  
Chamber  
Dust  
Cup  
PLEASE NOTE: The white pleated  
filter material in the HEPA dust cup  
filter will discolor over time -This is  
NORMAL and will NOT affect the  
performance of the filter. If the HEPA  
dust cup filter  
4. Remove the HEPA filter from the  
filter chamber. (Fig. 9)  
Filter  
1. To remove the dust cup (container),  
hold the unit in the upright position to  
prevent the dust from falling out of the  
dust cup. (Fig. 6)  
Fig. A  
Chamber  
HEPA  
Filter  
is properly  
"TapCleaned”  
after each use  
and suction  
Wash once a  
month or when  
suction  
appears  
reduced.  
.
does not return  
to 100%, then  
we suggest that  
the HEPA filter  
be “TapCleaned”  
vigorously until no  
Warning: Allow 24  
hours for drying before  
replacing in unit.  
Fig. 9  
more dust can be removed, then  
rinsed under the faucet and allowed to  
dry for 24 hours before refitting into  
the vacuum. (Fig. A) This should be  
done once a month or when  
5. Separate the debris screen from the  
HEPA filter cartridge by grasping the  
debris screen with one hand and the  
filter frame with the other and pull  
Fig. 6  
apart. (Fig. 10)  
Debris  
suction appears reduced.  
Screen  
CAUTION: The suction hole must be  
open and free of any obstructions at  
all times. Otherwise, the motor will  
overheat and could become  
damaged.  
HEPA  
Filter  
Fig. 10  
5
6
 
TROUBLE SHOOTING GUIDE  
ORDERING REPLACEMENT DUST CUP FILTERS  
FOR REPLACEMENT FILTER INFORMATION  
PROBLEM  
POSSIBLE REASON  
POSSIBLE SOLUTION  
for Model V1510  
1. Plug unit in firmly.  
2. Check fuse or breaker.  
Replace fuse/reset breaker.  
3. Call 1 (800) 798-7398.  
4. Turn the unit off and unplug  
from outlet.  
Call:  
1 (800) 798-7398  
1. Power cord not firmly plugged  
into outlet.  
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time  
Or visit our website:  
HAND VACUUM  
WILL NOT  
OPERATE  
2. No power in wall outlet.  
3. Needs servicing.  
4. Thermostat has tripped.  
Item  
Replacement HEPA Filter  
Part #  
1. Allow unit to cool down,  
then Restart. Empty dust  
cup – (see page 5).  
XF1510  
2. Turn unit off and unplug  
from wall outlet. Remove  
HEPA Dust Cup Filter and  
check for object(s) in air  
duct and remove.  
HAND VACUUM  
1. Dust cup is full.  
WILL NOT PICK-UP 2. Unit clogged.  
OR SUCTION  
POWER IS WEAK  
3. HEPA Dust Cup Filter needs  
cleaning or replacing.  
For Technical Support  
3. Clean or replace HEPA  
Dust Cup Filter.  
for Model V1510  
(see page 5)  
Call:  
1 (800) 798-7398  
Monday to Friday 8:30 A.M. - 5:00 P.M. Eastern Standard Time  
1. Empty dust cup.  
2. Review HEPA Dust Cup  
Filter instructions.  
1. Dust cup is full.  
DUST ESCAPING  
FROM HAND  
VACUUM  
2. HEPA Dust Cup Filter is not  
installed correctly.  
(see page 5)  
3. There is a puncture/hole in  
HEPA Dust Cup Filter.  
3. Replace HEPA dust cup  
filter. (see page 5)  
Please Note:  
HAND VACUUM  
HOSE OR  
BRUSHES WILL  
NOT PICK-UP  
1. Remove hose and/or  
brushes. Remove  
obstruction from hose.  
2. Empty and clean dust cup.  
The HEPA Dust Cup Filter is washable. It should, however, be replaced  
every six (6) months to ensure peak performance of your vacuum.  
1. Hose clogged.  
2. Dust cup is full.  
Important:  
Make sure that HEPA filter is completely dry before re-installing back in the  
hand vacuum.  
7
8
 
Model V1510  
ONE (1) YEAR LIMITED WARRANTY  
EURO-PRO Operating LLC warrants this product to be free from defects in material and  
workmanship for a period of one (1) year from the date of the original purchase, when  
utilized for normal household use, subject to the following conditions, exclusions and  
exceptions.  
If your appliance fails to operate properly while in use under normal household conditions  
within the warranty period, return the complete appliance and accessories. For Customer  
appliance is found to be defective in material or workmanship, EURO-PRO Operating  
LLC will repair or replace it free of charge. Proof of purchase date and $ 9.95 to cover the  
cost of return shipping and handling must be included. *  
Non-durable parts including, without limitation, dust cups, filters and brushes which  
normally require replacement are specifically excluded from warranty.  
The liability of EURO-PRO Operating LLC is limited solely to the cost of the repair or  
replacement of the unit at our option. This warranty does not cover normal wear of parts  
and does not apply to any unit that has been tampered with or used for commercial  
purposes. This limited warranty does not cover damage caused by misuse, abuse,  
negligent handling or damage due to faulty packaging or mishandling in transit. This  
warranty does not cover damage or defects caused by or resulting from damages from  
shipping or repairs, service or alterations to the product or any of its parts, which have  
been performed by a repair person not authorized by EURO-PRO Operating LLC.  
This warranty is extended to the original purchaser of the unit and excludes all other legal  
and/or conventional warranties. The responsibility of EURO-PRO Operating LLC if any,  
is limited to the specific obligations expressly assumed by it under the terms of the limited  
warranty. In no event is EURO-PRO Operating LLC liable for incidental or consequential  
damages of any nature whatsoever. Some states/provinces do not permit the exclusion  
or limitation of incidental or consequential damages, so the above may not apply to you.  
This warranty gives you specific legal rights, and you may also have other rights which  
vary from state to state.  
*Important: Carefully pack item to avoid damage in shipping. Be sure to include  
proof of purchase and to attach a tag to item before packing with your name,  
complete address and phone number with a note giving purchase information,  
model number and what you believe is the problem with item. We recommend you  
insure the package (as damage in shipping is not covered by your warranty). Mark  
the outside of your package “ATTENTION CUSTOMER SERVICE”. We are  
constantly striving to improve our products, therefore the specifications contained  
herein are subject to change without notice.  
9
Printed in China  
 

Sharp Copier AR 407 User Manual
Sharp Projector XG P20XU User Manual
Singer Sewing Machine 109 320 User Manual
Snapper Air Cleaner 31H700 User Manual
Sony Camera Lens SEL20F28 User Manual
Sony Printer iP1200 User Manual
Sunrise Medical Mobility Aid J Gel User Manual
Sylvania TV VCR Combo W6313CC User Manual
Tamron Camera Lens AFB016C700 User Manual
TANDBERG Network Router D1320202 User Manual