Sunpentown Intl Fan SF 609 User Manual

READ AND SAVE THIS INSTRUCTION MANUAL  
SUNPENTOW N  
Air Cooler  
Model SF-609  
Contents  
Functions  
1. Cooling, humidifying and air  
purifying  
Parts Name  
Product Appearance  
Control Panel  
2. Adopted photo-catalysis  
technology, Anti-bacterial water  
tank and germ-free water curtain  
cycle system  
Important Safety Notes  
Operation  
Specifications  
Circuit Diagram  
Maintenance  
3. Three fan air speeds with Sleep  
Mode function  
4. Automatic swing  
Trouble Shooting  
Your Guarantee  
5. Timer from half an hour to  
Seven and a half hours  
6. Castor wheels for portability  
7. Remote control  
8. Ionizer adopted  
Please read the instruction carefully  
prior to use.  
1
 
Important Safety Notes  
1. Make sure the correct power (120V/60 Hz) is supplied.  
2. To avoid electric shock or personal injury, do not operate any appliance with a  
damaged cord or plug or after the appliance malfunctions or has been damaged in  
any manner. Return the unit to Sunpentown (see warranty) for examination, repair or  
adjustment.  
3. Unplug the appliance when not in use and before maintenance or servicing.  
4. The applicable temperature to run this unit is betweenF3-1204F. Do not operate  
when the temperature is above or below this range. Do not let unit sit under direct  
sunlight.  
5. When the tank is full, move unit from the side slowly to prevent water from spilling.  
6. Do not place heavy objects on the machine.  
7. Close supervision is necessary when any appliance is used by or near children.  
8. When unplugging, pull from the plug and not on the cord.  
9. Turn off the unit when adding water.  
10.Turn off and unplug unit before cleaning.  
11.To avoid excessive dampness, do not use the humidifying function for an extended  
period of time in an area with poor circulation.  
12.When not planning to use the unit for a long period of time, please unplug the power  
cord, drain water, and store in a cool, dry place.  
13.Please change water often to keep the water tank clean. It is recommended to  
change the water once every 1 ~ 2 days.  
Operation  
Please fill the water tank as instructed below before turning on the unit.  
Operating instructions:  
1. ON/OFF button  
Press once to turn ON unit,he “H” indicator light of “SPEED” mode will be on.  
Press again to turn OFF unit.  
2. SPEED button  
When turned ON, the unit starts on High (the “H” indicator light is on), to adjust:  
o Press once for Medium speed (the “M” indicator light is on)  
o Press again for Low speed (the “L” indicator light is on)  
o Press again for High speed with Sleep mode (the “H” and “SLEEP” indicator  
lights are on).Unit will operate in High speed for 2 min, Medium speed for 1  
min, and back to High for 2 min. and so on for approx. 30 minutes. After which  
the unit will switch to operate in Medium speed for another 30 minutes and  
finally switch to Low speed. Unit will run in Low speed until powered OFF.  
o Press again for Medium speed with Sleep mode (the “M” and “SLEEP” indicator  
lights are on).Unit will run in Medium speed for 2 min, Low speed for 1 min,  
and back to Medium for 2 min. and so on for approx. 30 minutes. After which,  
the unit will switch to Low speed and continues in Low until powered OFF.  
o Press again for Low speed with Sleep mode (the “L” and “SLEEP” indicator  
lights are on).Unit will operate in Low speed for 2 min, stop 1 min, and back to  
Low for 2 min. and so on. Unit will continue to run in this mode until powered  
OFF.  
o There are total of six different settings to choose from.  
3
 
o To avoid catching a cold while sleeping, the Sleep mode will automatically  
decrease the fan speed slowlyT.imer can also be used in Sleep mode.  
3. SWING button  
Press the SWING button to select the swinging function:  
o Press once to turn on the swinging function (indicator light is on), which can  
cover 60° horizontally  
o Press again for fixed direction (indicator light is off)  
4. TIMER button  
Each press of the timer button will add 0.5 hour to the timer until it reached the  
maximum of 7.5 hours. Adding the numbers indicated equals the total time for the  
timer. For example: when the 0.5 and 1 indicators are on at the same time, it means  
the timer has been set for 1.5 hours; when the 0.5, 1, 2 and 4 indicators are on at  
the same time, the timer has been set for 7.5 hours. If none of the timer indicators  
are on, the unit will run continuously.  
5. COOL AIR (HUMIDIFYING) button  
o Press once to turn on the water pump, press again to turn off the water pump  
o If the water level is aboveMIN”, the red indicator light will turn on and the pump  
will start working. After 3 ~ 5 minutes, the unit will send out moist and comfortable  
cool air.  
o If the water level is belowMIN” or if the water tank is empty, please do not turn  
on this function. The unit will beep 5 times and the red indicator light will be  
flashing to warn that the water tank is low/empty and the pump will NOT work.  
o While operating in Cool Air / Humidifying mode, when the water tank reaches half  
point, the unit will bee5ptimesto warn you that the water tank is half empty. The  
red indicator light remains on and the unit continuous running.  
o To prevent damage to the water pump, when operating the unit without water,  
please keep the Cool Air / Humidifying function OFF. The unit will operate as a  
normal electric fan.  
6. ION button  
o Press once to turn the ION function on (indicator light is on)  
o Press again to turn ION function off.  
7. WATER FILLING INSTRUCTIONS  
o Please be sure the power is OFF before filling water.  
o Fill the water tank by pouring water and adding ice into the Ice & Water Inlet.  
o Amount of water added can be seen from the water indicator located at the  
bottom front.  
o Make sure the water indicator indicates the water level is aboMvIeN“.  
o Pour in 2/3 of water (6 Liters) and 1/3 of ice (3 Liters) for best cooling effect.  
o You can also put some ice or ice packs in the “Ice Box” located on the top of the  
unit for extra cooling (optional).  
o DO NOT add more than 10 Liters of water into the water tank. The water indicator  
light should never rise abovMe AX” or the water tank will overflow.  
NOTE: When operating the unit for the first time, please add water to the  
“MAX” level.  
4
 
Specifications  
Model  
Rated  
Voltage  
Rated  
Frequency Power  
60Hz  
Rated  
Water  
Consumption  
Water Tank Speed  
Capacity  
Dimensions  
N.W.  
SF-609  
~120V  
60W  
0.6-0.7L/h  
10L  
7m/s  
5.4”x11.8”x25.2”  
16.5lb  
s
Circuit diagram  
N
E
L
LeafMotor  
Water Pump  
MotorCapacitor  
L N  
M L  
H
COOL F/R  
PCB  
SirenPCB  
MainMotor  
CircuitDiagram  
Maintenance  
Cleaning the filter net and water tank  
Pull out  
water tube  
It shouldbe  
putin thesun  
Photocatalysisfilter net  
can'tbewatered  
Watercurtain  
Filter shelf  
Rearpanel  
Dust filter net  
Photocatalysis  
filter net  
(Figure1)  
(Figure4)  
(Figure2)  
(Figure3)  
To ensure best humidifying and purifying effect, please clean the filtration system once  
a week.  
1. Pull the dust filter net upwards from opening slot of filter shelf  
2. Remove the photo-catalysis filter net (small black filter)  
3. Rinse the dust filter net with clean water and allow to dry  
4. Replace the photo-catalysis filter net and insert the dust filter net back in place  
o Do not wet the photo-catalysis filter (figure 3), insolate it in the sun (figure 4)  
5
 
Troubleshooting  
Problem  
Reasons  
Solution  
 Turn on power  
 Switch off Timer mode  
 Power is not turned on  
 Timer fulfilled  
Not blowing air  
 Unit is broken/defective  
 Contact Sunpentown  
 "On/Off" button not pressed  Press the “On/Off” button  
Unit will not turn off  
 Unit is broken/defective  
 Contact Sunpentown  
 Take off rear panel and filter  
net, remove foreign object(s)  
 Contact Sunpentown  
 There are objects in it  
 Faulty motor  
 Air wheel/fan is loose  
Unit makes noise  
 Contact Sunpentown  
 Water level low/empty  
 Faulty water pump  
 Add water to Maximum level  
 Contact Sunpentown  
Not humidifying  
No swing  
 “Swing” button not pressed  Press the “Swing” button  
 Faulty leaf motor  Contact Sunpentown  
Your Guarantee  
If this product is found to be faulty as a result of faulty materials or workmanship within  
one year from date of purchase, it will be repaired or replaced free of charge.  
This guarantee is subject to the following terms:  
1. Sunpentown must be notified of the fault.  
2. Proof of purchase must be presented to Sunpentown’s nominated representative.  
3. The warranty will be void if the product is modified, misused or repaired by an  
unauthorized person.  
4. The guarantee after repair or replacement will not be extended beyond the  
original one-year period.  
5. All replacement parts or units will be new or reconditioned.  
6. Parts or units, which are replaced, become the property of Sunpentown.  
7. The warranty applies for the use of the product in the USA.  
8. Warranty does not include freight charges.  
This GUARANTEE is in addition to your Statutory Rights.  
SUNPENTOWN INTERNATIONAL INC.  
18249 Valley Boulevard, City of Industry, CA 91744  
Tel: 626-581-1818 Fax: 626-581-1398  
6
 

Sharp Microwave Oven R 22AT User Manual
Soleus Air Air Conditioner PH3 09R 03 User Manual
Sony Microcassette Recorder M 670V User Manual
Sony Speaker SA WX900 User Manual
Sony Video Games PEG S360 User Manual
Speco Technologies Computer Monitor VM 1401C User Manual
Stiga Lawn Mower PARK PRO 20 CAT User Manual
Sun Microsystems Server 2005Q2 User Manual
SV Sound Speaker PB13 User Manual
Tanaka Trimmer HTD 2522PF User Manual