SP AF 11~18 mm F/4.5-5.6
Di-II LD Aspherical [IF]
(Model A13)
Thank you for purchasing the Tamron lens as the latest addition to your
photographic equipment. Di II lens (Digitally Intigrated) series are
designed for digital SLR cameras with image sensors equivalent to APS-
C size. Before using you new lens, please read the contents of this
Owner's Manual thoroughly to familiarize yourself with your lens and
the proper techniques for creating the highest quality images possible.
With proper handling and care, your Tamron lens will give you many
years of photographing beautiful and exciting pictures.
NOMENCLATURE
1.
2.
3.
4.
5.
6.
7.
8.
9.
Lens Hood
Hood attaching alignment mark
Hood attaching indicator
Filter Ring
Hood attaching bayonet ring
Distance index
Distance scale
Focusing ring
Zooming ring
10. Focal length scale
11. Zoom index mark
12. Zoom lock switch (A16) Figs 3 & 4
13. Lens mount/Lens mount contacts (Nikon)
14. AF-MF altering switch (Canon Fig 5 & 6)
15. Lens attachment mark
16. Bayonet tab on the hood
17. Bayonet tab on the lens
SPECIFICATIONS
A13
11-18mm
F/4.5-5.6
103 29'-75 33'
12/15
Focal Length
Maximum Aperture
Angle of View
Lens Construction
Minimum Focus Distance
Filter Size
0.25m
77mm
Length
78.6mm
83.2mm
345g
Diameter
Weight
Hood
DA13
* Lengths and weights listed in lens specifications are for lenses with Nikon mounts.
* Features and cosmetic designs of lenses listed in this owner's manual may be revised
without notice.
ATTACHING LENS TO CAMERA
How to mount the lens
Removing the rear cap of the lens, align the lens attachment mark on the lens barrel with its
counterpart on the lens mount of the camera and insert the lens mount into the camera's
mount opening. Rotate the lens clockwise until it click-locks. For Nikon models, align the
lens attachment mark with the dot on the camera and rotate the lens counter-clockwise
until it click-locks.
How to detach the lens
Pressing the lens release button of the camera down, turn the lens counter-clockwise (clock-
wise in case on Nikon), and lift the lens off the camera's lens mount.
* For further details, please read the instruction manual of your camera.
FOCUSING (Autofocus) (Ref. Figs. 1 & 2)
Set the camera on the autofocus mode (AF). Press the shutter button lightly while viewing
through the camera's viewfinder, the lens focuses automatically. An in-focus mark will light
when lens focuses on the main subject sharply. Press the shutter button further to photo-
graph.
* Also, please read the camera's instruction booklet carefully.
When set on AF mode, be very careful not to hinder the autofocusing movements of
the lens. Such interference may cause a serious damage on the lens mechanism.
Select between the autofocus and manual focus modes by the AF/MF mode selector
switch on the lens barrel.
* For further details, please read the instruction manual of your camera.
FOCUSING (Manual Focus) (Ref. Fig. 2)
Switch the focusing mode switch of the camera to manual focusing mode (MF) in
case of Nikon, Minolta, or Pentax camera. In case of Canon, switch to MF on the AF-MF alter-
ing switch on the lens barrel. Focus manually, rotating the focusing ring while viewing
through the camera's viewfinder. The main subject image in the viewfinder will be critically
sharp on the viewfinder screen as lens focuses rightly.
Press the shutter button lightly while operating the lens for focusing. The focus aid
mark in the viewfinder will light up when the subject is in critical focus.
Make sure the subject at infinity appears sharp in the finder when in focus. Because,
the infinity position on the lens is made with certain allowance to assure right focus under a
wide variety of photographing conditions.
* For further details, please read the instruction manual of your camera.
ATTACHING AND REMOVING THE LENS
How to mount the lens
Remove the rear cap of the lens. Align the lens attachment mark (15) on the lens barrel with
its counterpart on the camera mount and insert the lens. Rotate the lens clockwise until it
click-locks. For Nikon and Pentax models, align the lens attachment mark on the camera and
the lens attachment mark (15) on the lens to attach the lens. For Nikon models, align the
lens attachment mark with the dot on the camera and rotate the lens counter-clockwise
until it click-locks.
How to detach the lens
Pressing the lens release button on the camera down, turn the lens counter-clockwise (in
case of Nikon lens, clockwise), and lift the lens off the camera's lens mount.
The image circles of Di-II lenses are designed to match the digital SLR cameras using the image sen-
sors equivalent to APS-C (approx. 15.5 x 23.2mm). Do not use Di-II lenses with cameras using image sensors
larger than APS-C. Using Di-II lenses with such cameras may cause vignetting on the image.
Some Canon digital SLR cameras have index marks for attaching both EF lenses (red) and EF-S lens-
es (white) on the bayonet mount. To attach Tamron Di-II lenses, align the lens attachment mark on the lens
(15) with the index mark for EF lenses (red). Do not forcibly align the indicator on the kens (15) with the
index mark for EF-S lens (white). Doing so could result in damage to the lens and/or camera.
For further details, please read the instruction manual of your camera.
FOCUSING (Autofocus) (Ref. Figs 1 & 2)
Switch the focusing mode switch of the camera to Auto focusing mode (AF) in case of
Nikon, Konica Minolta, or Pentax. In case of Canon camera, switch the AF/MF switch (14) on
the lens to AF. (Fig. 5). Press the shutter button lightly while viewing through the camera's
viewfinder, the lens focuses automatically. An in-focus mark will light when the lens focuses
on the main subject sharply. Press the shutter button further to photograph.
When set on AF mode, interfering with focusing ring (8) may cause serious damage to the lens
mechanism.
For further details, please read the instruction manual of your camera.
ZOOMING (Ref. Fig. 2)
Rotate zooming ring (9) of the lens while viewing through the camera's viewfinder and
compose your image at the chosen focal length.
ZOOM LOCK SWITCH (Ref. Figs. 3 & 4)
Model A16 is equipped with zoom lock switch mechanism which prevent lens barrel from
extending towards long focal length, while hanging around the neck. Activate the switch at
the shortest setting to stop the lens barrels from rotating and extending.
How to activate the zoom lock switch mechanism
1. Locking: Set the zoom ring on the lens to the shortest position. Move the zoom lock
switch (12) toward the camera for locking the zooming ring (9). The lens barrel is locked in
position when the portion beneath "Lock" is shown in red and the lens barrel does not
rotate or extend by its own weight.
2. Releasing: Push the zoom lock switch (12) up. The zooming ring (9) is now released and
can be rotated.
Zoom lock switch cannot be activated unless the lens is set to the shortest position. Do not force the
lock switch or try to rotate the zooming ring while locked; doing so may damage the lens.
The zoom lock mechanism is made to prevent the lens barrel from extending while carried around
the neck. When not locked, the zoom lens may change its focal length during a long exposure used in a low
or high angle position.
The lens can be used at the shortest setting for picture taking even while in the focused position.
LENS APERTURE AND AE MODE
Please follow the instruction manual of your camera.
LENS HOOD (Ref. Figs. 1, 7, 8, 9)
A bayonet-type lens hood is provided as standard equipment. We recommend shooting
with the hood attached whenever possible as the lens hood eliminates stray light which is
harmful to the picture. However, please be aware of the precautions written below when
your camera is equipped with a built-in flash.
Attaching the Lens Hood (Ref. Figs. 7 & 8)
Align the index mark (2) on the hood with the corresponding index mark (5) or the top of
the index line of the distance scale, on the lens. Press the hood lightly onto the hood attach-
ing bayonet ring (Fig. 7, No. 1) and then rotate it clockwise to secure (Fig. 7, No. 2). The lens
hood will be securely held as the mark "TAMRON O" comes to the top (Fig. 8, No. 3). When
attaching the lens hood, hold the focusing and zoom control rings so that they are not
rotated unintentionally.
Pay particular attention to align the hood attaching indexes when using zoom lenses including
wide-angle (ex. 35mm or wider) settings. Improper attachment of a hood for wide-angle zoom lens may
cause large shadowed areas in your pictures.
Stowing lens hood on the lens (Ref. Fig. 9)
1. Reverse the lens hood. Point the lens toward the opening, then align the hood attach-
ment mark on the lens with the (TAMRON O) alignment on the hood (3).
2. Turn the hood clockwise until its alignment mark is at the top to set it. (Fig. 9, 2)
PRECAUTIONS IN SHOOTING
The optical design for Di-II takes into consideration the various features of digital sin-
gle reflex cameras. However, due to the configuration of the digital SLR cameras, even when
the Autofocus accuracy is within specifications, the focal point may be a little forward or
behind the optimum point when shooting with auto focus under some conditions.
The image circles of Di-II lenses are designed to match the digital SLR cameras using
the image sensors equivalent to APS-C (approx. 15.5 x 23.2mm). Do not use Di-II lenses with
such cameras may cause vignetting on the image.
A13 employs an internal focusing (IF) system. Because of the characteristics of this
optical design, the angles of view at distances other than infinity are wider than that of the
lenses applying an ordinary focusing system.
When the built-in flash on the camera is used, adverse photographic phenomena
such as corner illumination, fall-off, or vignetting at the bottom part of the image may be
observed, especially with wide angle ranges. This is due to the inherent limitation of the
coverage of the built-in flash, and/or the relative position of the flash to the edge of the lens
barrel which causes shadows on the image. It is strongly recommended to use a suitable
separate flash unit provided by the camera manufacturer for all flash photography.
When using the lens in the telephoto focal range, please be careful with the camera
shake. Effective way to avoid the camera shake is using an ISO setting of higher numbers.
Using a tripod or monopod is also effective.
When set on AF mode, interfering with the focusing ring may cause serious damage
to the lens mechanism.
Certain camera models may indicate the maximum and minimum aperture values of
the lenses appropriate numbers. This is inherent to the design of the camera and not an
indication of error.
When using a special filter such as a PL filter on the A16, use low-profile filters. The
thick rim of a normal filter may cause vignetting.
TO ENSURE LONG-TERM SATISFACTION
Avoid touching the glass element surface. Use a photographic lens cloth or a blower
to remove dust from the lens element surface. When not using the lens, always place a lens
cap on it for protection.
Use a lens cleaning tissue or lint cloth with a drop of cleaning solution to remove fin-
gerprints or dirt on the glass lens surface with a rotary motion from the center to the edges.
Use a silicon cloth to clean your lens barrel only.
Mildew is an enemy of your lens. Clean the lens after shooting near water or in any
humid place. Store your lens in a clean, cool, dry place. When storing your lens in a lens case,
store it with commercially available drying agents such as silica gel, and change the agent
occasionally. If you find mildew on your lens, consult an authorized repair shop or nearby
photographic store.
Do not touch the lens-camera interface contacts since dust, dirt and/or stains may
cause a contact failure between the lens and camera.
When using your equipment in an environment where the temperature changes from
one extreme to another, make sure to put your equipment temporarily in a case or a plastic
bag for a length of time in order for the equipment to go though a gradual temperature.
This will reduce potential equipment trouble.
|